GetPsuInfo
Gets the current PSU information from the managed system.
Syntax
OOB
saa -i <IP or host name> -u <username> -p <password> -c GetPsuInfo
In-Band
saa [-I Redfish_HI -u <username> -p <password>] -c GetPsuInfo
Multiple Systems OOB
saa -l <system list file> -u <username> -p <password> -c GetPsuInfo
Options
None.
Examples
OOB
[SAA_HOME]# ./saa -i 192.168.34.56 -u ADMIN -p PASSWORD -c GetPsuInfo
In-Band
[SAA_HOME]# ./saa -c GetPsuInfo
[SAA_HOME]# ./saa -I Redfish_HI -u ADMIN -p PASSWORD -c GetPsuInfo
Multiple Systems OOB
[SAA_HOME]# ./saa -l SList.txt -u ADMIN -p PASSWORD -c GetPsuInfo
Output
Via Redfish
[Module 1]:
PWS Module Number: PWS-2K07A-1R
PWS Serial Number: P2K7ACN32PB0126
PWS Module Revision: 1.0
Firmware Version: 1.0
Status: OK
AC Input Voltage: 116 V
AC Input Current: 0.94 A
DC 12V Output Voltage: 12.10 V
DC 12V Output Current: 7.04 A
Temperature 1: 40 C / 104 F
Temperature 2: 62 C / 144 F
Fan 1: 12448 RPM
Fan 2: 0 RPM
DC 12V Output Power: 85 W
AC Input Power: 108 W
Current Sharing Control: Active
Via PMBus
[Module 1](SlaveAddress = 0xB0)
PWS Module Number: PWS-2K09A-1R
PWS Serial Number: P2K09CN53IB0413
PWS Module Revision: 1.0
PMBus Revision: 0x22
Status: OK
AC Input Voltage: 114.00 V
AC Input Current: 0.98 A
DC 12V Output Voltage: 12.15 V
DC 12V Output Current: 7.38 A
Temperature 1: 34 C / 93 F
Temperature 2: 56 C / 133 F
Fan 1: 6048 RPM
Fan 2: 0 RPM
DC 12V Output Power: 89 W
AC Input Power: 111 W
Current Sharing Control: Active - Active (90)
Notes
- The console output may vary when getting PSU info through different interfaces, depending on the BMC version.
- If the execution Status field of the managed system shows SUCCESS, the console output of the managed system will be shown in the Execution Message section of the created log file.