ChassisIntrusion
Gets and clears the status of the chassis intrusion sensor. If a hardware intrusion is detected, the status is "Hardware Intrusion"; otherwise it is "Normal". This command can either get the status or set the status to "Normal".
Syntax
OOB
saa -i <IP or host name> -u <username> -p <password> -c ChassisIntrusion --action {Clear | Status}
In-Band
saa [-I Redfish_HI -u <username> -p <password>] -c ChassisIntrusion --action {Clear | Status}
Multiple Systems OOB
saa -l <system list file> [-u <username> -p <password>] -c ChassisIntrusion --action {Clear | Status}
Options
--action <action>: Sets action:1= Status2= Clear
Examples
OOB
[SAA_HOME]# ./saa -i 192.168.34.56 -u ADMIN -p PASSWORD -c ChassisIntrusion --action Status
In-Band
[SAA_HOME]# sudo ./saa -i 192.168.34.56 -u ADMIN -p PASSWORD -c ChassisIntrusion --action Clear
Multiple Systems OOB
[SAA_HOME]# ./saa -l SList.txt -u ADMIN -p PASSWORD -c ChassisIntrusion --action Status
SList.txt:
192.168.34.56
192.168.34.57
If the execution "Status" field for a managed system is SUCCESS, the chassis intrusion information of the managed system is shown in the "Execution Message" section in the created log file.
Output
Status
Managed system................localhost
Intrusion Sensor..........Normal
Clear
Chassis intrusion has already been cleared.